Engineering > EXAM > 3rd Class Stationary Steam Engineer License Prep - Complete Solutions (Answered) (All)

3rd Class Stationary Steam Engineer License Prep - Complete Solutions (Answered)

Document Content and Description Below

3rd Class Stationary Steam Engineer License Prep - Complete Solutions (Answered) __________ steam turbines allow condensate to be reclaimed for use in the system Condensing With water at a temperatu... re of 212°f, 1 bhp is equivalent to the evaporation of 34.5 lb of water every ________ hour(s) 1 In a closed feedwater heater, the _________ Steam and water do not mix Sensible heat is heat that ______ changes the temperature of a substance but not its state When performing a hydrostatic test on a boiler, the safety valve must be. ________ removed from the boiler and the opening blank or gagged If repairs are to be made on a safety valve, they must be made by the. _______/ manufacturer of the safety valve or authorized representative The proper way to stop a steam turbine when taking it off line is to _______ trip the over speed device by hand Approximately. _______^ of air is required to completely burn 1 lb of fuel oil 15 lb In order to reduce the viscosity of a fuel oil, it's. _______ temperature must be increased What are is prevented from backing up into the steam line on a deaerator ________ an internal overflow or a loop seal A steam pressure gauge must have a range of at least. _______ 1 1/2 time's the mawp Electrostatic precipitators are used in the power plants to ________ remove fly ash from gases of combustion Valve located between the boiler and water column must be ______ locked or sealed open The boiling point of water. ________ with an increase in pressure increases A hole is drilled in the end of a staybolt _______ to warn of a corroded stay When taking a boiler off line, a vacuum is prevented by. _____ opening the air cock A valve that requires five 360° turns of the hand wheel to change from fully open to fully closed is a. _______ valve slow opening A thermostatic steam trap opens when the ______ Bellows contract A combustion control on a boiler. _______ controls the air-fuel ratio When coal is classified, ________ refers to hardness Rank _______ gauge glasses are used on boilers with precious exceeding 250 psi Flat Oxygen and non condensable gases are removed from feed water by ________ heating the water __________ combustion is when all fuel is burned using only the theoretical amount of air Perfect Water tube boilers require less water than. _________ boilers fire tube A boiler equipped with a draft gauge and registering a negative pressure indicates. _________ atmospheric pressure is greater than furnace pressure Pressure atomizing burners atomized fuel oil using _______ a nozzle The _________ on the steam turbine functions as a limit switch overspeed trip Circulating water passes through a surface condenser. ________ inside the tubes The Pour point of a fuel oil is. ________ the lowest temperature at which oil will flow A condensate pump is located 75 ' below the feed water heater and its discharged gauge reads 75 PSI. The pressure at the inlet to the heater is. _______ psi 42.525 A boiler burning fuel oil and using forced-draft requires. ________ cu ft a furnace volume per boiler horsepower .75 A boiler evaporates 48,000 lb of steam/hr. it evaporates 12 lb of steam/sq ft of heating surface per hour. The boiler has _______ as ft of heating surface 4000 a steam turbine exhaust end and condenser are prevented from excess pressure by ________ the atmospheric relief valve At 0 psi, _______ btu are necessary to change 1 lb of water from and at 212°f into steam 970.3 Automatic toilets are program to ignite the burner ______ in lowfire ________ boilers can operate at higher pressures than fire tube boilers water tube The first step when using a soot blower is ________ open Steam line drain The purpose of a vent on an open feedwater heater is to _______ remove air and other non-condensable gases Cooling water and steam are in in direct contact with each other in a(n) ________ condenser Surface A boiler with 3450 sq ft of heating surface design for 5 sq ft of heating surface / BHP has ________ hp 690 A water column _________ dampens fluctuating water level A closed feedwater heater is always installed. ________ [Show More]

Last updated: 2 weeks ago

Preview 1 out of 18 pages

Reviews( 0 )

$15.00

Add to cart

Instant download

Can't find what you want? Try our AI powered Search

OR

GET ASSIGNMENT HELP
14
0

Document information


Connected school, study & course


About the document


Uploaded On

Apr 17, 2024

Number of pages

18

Written in

Seller


seller-icon
Ajay25

Member since 3 years

131 Documents Sold


Additional information

This document has been written for:

Uploaded

Apr 17, 2024

Downloads

 0

Views

 14

Recommended For You


$15.00
What is Browsegrades

In Browsegrades, a student can earn by offering help to other student. Students can help other students with materials by upploading their notes and earn money.

We are here to help

We're available through e-mail, Twitter, Facebook, and live chat.
 FAQ
 Questions? Leave a message!

Follow us on
 Twitter

Copyright © Browsegrades · High quality services·