Education > QUESTIONS and ANSWERS > EPA 608 Core and Types 1-3 Exam Questions with correct Answers (All)

EPA 608 Core and Types 1-3 Exam Questions with correct Answers

Document Content and Description Below

On low pressure chillers, moisture typically enters the refrigerant system through - Answer- air leaks from areas with gaskets or fittings The maximum test pressure for leak testing a low pressure ... centrifugal is: - Answer- 10 psig Leak test and repair the chiller to reduce refrigerant loss from a pruge unit on CFC-11 chiller - Answer- ... A hydrostatic tube test kit is used to: - Answer- determine if a tube leaks Commercial and industrial process refrigeration systems must be repaired when the leak rate exceeds ____ of the charge per year. - Answer- 35% Refrigerant recovery typically start with liquid recovery it is faster. - Answer- ... A rupture disc on a recovery vessel for a low pressure refrigerants relieves at: - Answer- 15 psig According to ASHRAE Guideline 3-1996, if the pressure in a system rises from 1 mm Hg to a level above ____ during a standing vacuum test, the system should be checked for leaks. - Answer- 2.5 mm Hg The primary water source for a recovery unit condensing coil is _____. - Answer- local municipal water supply When recharging a refrigeration system with R-11, what vaporpressure is necessary in the shells before changing with liquid? - Answer- 16.9" Hg vacuum After recovering the liquid refrigerant you must: - Answer- recover the vapor refrigerant According to the EPA there is approximately _____ refrigerant vapor left in an average 350 ton R-11 chiller at 0 psig pressure once all the R-11 liquid has been removed. - Answer- 100 pounds Charging refrigerant liquid into a refrigeration system when it is under a 29 inch Hg vacuum can cause the: - Answer- system water to freeze A system does not have to be evacuated all the way to the required level when: - Answer- leaks in the appliance make evacuation to the prescribed level unattainable Which of the foloowing repairs would ALWAYS be considered "major" under EPA's - Answer- replacement of evaporator coil Under EPA's regulation's _______ is used to pressurize a low pressure chiller for the purpose of opening the system for a non major repair? - Answer- warming the refrigerant If you are using a recovery machine manufactored AFTER 11-15-93 you must evacuate an low pressure appliance to _______ before making a major repair. - Answer- 25 mm of Hg absolute After reaching the required recovery vacuum on a chiller, you should - Answer- Wait for at least a few minutes to see if the system pressure rises, indicating that there is till refrigerant in a liquid form or in the oil The pressure corresponding to 32 F for R-123 - Answer- 20 inches of HG vacuum When evacuating a system the use of too large a vacuum pump can cause? - Answer- trapped water to freeze Refrigerant-11 at a pressure of 17 inches HG vacuum has a saturation temperature of: - Answer- 35F During the evacuation of a system containing large amounts of moisture you can prevent freezing of this moisture by increasing the pressure with______gas - Answer- nitrogen ASHRAE standard 15-1994 requires that each machinery room must activate an alarm and mechanical ventilation beofre refrigerant concentrations exceed: - Answer- the threshold limit valve and time weighted average The typical design burst pressure for a rupture disk on a low pressure centrifugal air-conditioning system is set at_______ - Answer- 15 psi Heat pumps that have been retrofitted from R22 to R407C should be leak checked with: - Answer- pressurized nitrogen When a new system has been assembled, the first thing to do is: - Answer- pressurize the system with inert gas and leak check EPA regulations require that leaking commercial or industrial process refrigeration equipment must be repaired when the leak rate exceeds______ of the charge per year. - Answer- 35% Prior to replacing the condenser coil in a high pressure system, the refrigerant was recovered and stored in a refillable container. The refrigerant: - Answer- can probably be charged back into the system R-410A requires recovery tanks rated for at least: - Answer- 400 psig to recover liquid refrigerant you must connect one hose to the - Answer- liquid line The primary water source for cooling the condenser of a water-cooled recovery unit is: - Answer- local municipal water supply After refrigerant liquid has been recovered from a system, any remaining vapor is: - Answer- condensed by the recovery system the recovery of refrigerant from a system as a vapor only will minimize the loss of: - Answer- oil When using recovery or recycling equipment that was made after 11-15-93 you must evacute a system containing MORE than 200 pounds of CFC-12 to ________ before making a major repair. - Answer- 15 inches of HG vacuum With an air-cooled condenser on the roof of a building and the evaporator on the first floor, recovery should first occur: - Answer- from the liquid line entering the evaporator When using recovery or recycling equipment that was made BEFORE 11-15-93 technicians must evacuate a unit that has a normal charge of 10 pounds of CFC-500 to _____ before disposing of the system. - Answer- 4 inches of HG vacuum A system can be evacuated to only atmospheric pressure when: - Answer- leaks in the appliance make the evacuation to the prescribed level unattainable To change the compressor on a system cantaining 40 pounds R-500 using a recycling machine that was manufactured AFTER 11-15-93 you must isolate the compressor then: - Answer- evacuate the isolated section of the system to 10 inches of vacuum and hold. If the system pressure does not rise, remove the compressor. Recycling and recovery equipment maufactured after 11-15-93 does not need an oil separator - Answer- ... To change the compressor on a system containing R-410A, you must isolate the compressor then: - Answer- Evacuate the isolated section of the system to atmospheric pressure and hold. If system pressure does not rise, remove the compressor. System- dependent recovery equipment CANNOT be used when: - Answer- the appliance contains over 15 pounds of refrigerant Moisture is removed a system by: - Answer- using a filter drier When a unit is opened for servicing the ______ should always be replaced - Answer- filter drier The backseating of a suction shutoff valvee will close the: - Answer- guage port When charging an R-12 refrigeration system that uses a water cooled condensor, you must first charge with vapor to a pressure of at least _____ , before switching to a liquid charging. - Answer- 35 psig A compressor heater is used to: - Answer- reduce the amount of refrigerant in the lubricating oil While R-410A is a high pressure refrigerant, it can be stored in the back of your service van as long as: - Answer- the temperature inside the vehicle does not exceed 125 degrees F. This is the same guidance given for R-22 and other common refrigerants. For what refrigerant is an equipment room refrigerant monitor required under ASHRAE standard 15? - Answer- R-123 A reciprocating compressor should not be energized if the - Answer- discharge service valve has closed What factor affects the speed of evacuation? - Answer- the size of the equipment the ambient temperature the amount of moisture in the system The evacuation of a system is a method of: - Answer- dehydration When moisrture exists in an operating system which is likely to occur? - Answer- Acid will form The over-evacuation of a system: - Answer- does not occur A system is considered dehydrated when: - Answer- the vacuum indicator shows you have reached & held the required finished vacuum When evacuating a system the hoses should be: - Answer- equal to or larger than the vacuum pump inlet connection When evacuating a system the hoses should be: - Answer- short in length & as large in diameter as possible When operating refrigerant recovery or recycling equipment the following precautions should be taken - Answer- safety glasses & gloves along with following equipment safety precautions The color code for refrigerant recovery cylinders is - Answer- yellow tops with grey bodies Never use oxygen or compressed air to pressurize a sytem because: - Answer- when mixed with compresser oil or some refrigerants it could explode what type of refrigerant is clorine free - Answer- HFC's When using any solvent, chemical, cleaner, chemical or refrigerant you should review - Answer- MSDS (data sheets) Refrigerant vapors or mist should not be inhaled because - Answer- they may cause heart irregularities & or unconsciousness When using recovery unit the fill level of the recovery tank can be controlled by - Answer- mechanical float switch electronic shutt-off device weight HCFC - Answer- R-22 R-123 R-124 it is necessary to place a refrigerant label on: - Answer- a frigerant cylinder that is being returned for reclaiming DOT requires youdo this when transporting cylinders - Answer- attach DOT [Show More]

Last updated: 10 months ago

Preview 1 out of 32 pages

Also available in bundle (1)

EPA 608/HVAC: EPA 608 Exam Bundle

epa 608 universal exam with complete solutions HVAC (EPA Certification Exam Section 608) Questions and Answers EPA 608 9th edition Questions and Answers (Graded A) EPA 608 Type 2 Practice exam wi...

By Nancylect 10 months ago

$25

22  

Reviews( 0 )

$9.00

Add to cart

Instant download

Can't find what you want? Try our AI powered Search

OR

GET ASSIGNMENT HELP
80
0

Document information


Connected school, study & course


About the document


Uploaded On

Jul 01, 2023

Number of pages

32

Written in

Seller


seller-icon
Nancylect

Member since 2 years

99 Documents Sold


Additional information

This document has been written for:

Uploaded

Jul 01, 2023

Downloads

 0

Views

 80

Recommended For You

What is Browsegrades

In Browsegrades, a student can earn by offering help to other student. Students can help other students with materials by upploading their notes and earn money.

We are here to help

We're available through e-mail, Twitter, Facebook, and live chat.
 FAQ
 Questions? Leave a message!

Follow us on
 Twitter

Copyright © Browsegrades · High quality services·