NATE Industry Competency Exam: Commercial Refrigeration | 100 Questions with 100% Correct Answers

Document Content and Description Below

With the condensing pressure and compressor speed remaining constant, a decrease in suction pressure will cause a(n): a. Decrease in compressor capacity and decrease in current. b. Increase in comp... ressor capacity and decrease in current. c. Increase in compressor capacity and increase in current. d. Decrease in compressor capacity and increase in current. - ✔✔D An indication of non-condensable gas in a refrigeration system is significantly: a. Lower-than-normal suction pressures. b. higher-than-normal suction pressures. c. Lower-than-normal head pressures. d. higher-than-normal head pressures. - ✔✔D An automatic expansion valve controls refrigerant flow to an evaporator by maintaining a constant: a. Suction pressure. b. Pressure differential across the valve port. c. Liquid line pressure. d. Superheat. - ✔✔A What is the approximate compression ratio of a compressor operating at 35 psig suction pressure and 135 psig discharge pressure? a. 1:03. b. 3:01. c. 1:04. d. 4:01. - ✔✔B The BTUs rejected at the condenser are always greater than the heat absorbed in the evaporator because: a. The condenser is mounted outside with restricted airflow. b. Of the high temperature of the discharge vapor and length of the discharge line. c. Of the inefficiency of the condenser and pressure drop in the discharge line. d. Of the heat of compression in the compressor. - ✔✔D A unit cooler is inspected and found to be completely iced up. The heaters and defrost timer are found to be working properly. A technician should:a. Adjust the defrost termination switch to a higher temperature setting. b. Adjust the thermostatic expansion valve to a higher superheat setting. c. Clear all of the ice from the coil and find out why the coil is frosted. d. Increase the frequency of the defrost cycle. - ✔✔A what is the correct gauge pressure corresponding to an absolute pressure of 24.7 psia at sea level? a. 10 psig. b. 12.6 psig. c. 39.4 psig. d. 39.7 psig. - ✔✔A For a lineup of medium temperature case, an evaporator temperature 0f 23°F is needed. The following conditions exist: · The suction line pressure drop is equivalent to approximately 2°F. · The liquid line pressure drop is equivalent to 1°F. The compressor capacity should be selected based on a saturated suction temperature of: [Show More]

Last updated: 1 year ago

Preview 1 out of 18 pages

Also available in bundle (1)

Bundle for NATE Tests Compilation

Bundle for NATE Tests Compilation

By Tessa 1 year ago

$30

7  

Reviews( 0 )

$10.00

Add to cart

Instant download

Can't find what you want? Try our AI powered Search

OR

GET ASSIGNMENT HELP
75
0

Document information


Connected school, study & course


About the document


Uploaded On

Aug 09, 2022

Number of pages

18

Written in

Seller


seller-icon
Tessa

Member since 2 years

542 Documents Sold


Additional information

This document has been written for:

Uploaded

Aug 09, 2022

Downloads

 0

Views

 75

Document Keyword Tags

Recommended For You


$10.00
What is Browsegrades

In Browsegrades, a student can earn by offering help to other student. Students can help other students with materials by upploading their notes and earn money.

We are here to help

We're available through e-mail, Twitter, Facebook, and live chat.
 FAQ
 Questions? Leave a message!

Follow us on
 Twitter

Copyright © Browsegrades · High quality services·