Disaster Management > QUESTIONS & ANSWERS > FF2 Exam Prep 2022 (NATIONAL); Questions and answers; IFSTA Essentials of Firefighting Exam Prep (Fo (All)
FF2 Exam Prep 2022 (NATIONAL); Questions and answers; IFSTA Essentials of Firefighting Exam Prep (For FF2) A description of conditions as they appear can also be called a Correct Answer-Brief Initi... al Report The arrival report should contain the Correct Answer-Address of incident if different from original What contains the transfer of command? Correct Answer-Personal accountability report What includes an air consumption report when given? Correct Answer-Tactical progress report What is intended to warn personnel at a scene of an impending hazard? Correct Answer-Emergency radio traffic What would be a systematic method of confirming the status of units operating at incident? Correct Answer-Personal accountability report What is a limitation of a personnel accountability report? Correct Answer-It uses a considerable amount of time What is vital to fire department operations from legal, statistical, and record-keeping standpoints? Correct Answer-Post Incident report Why was the National Fire Incident Reporting System (NFIRS) developed? Correct Answer-To create data for analysis Knowing about types of roofs, roofs supports, and roof coverings can help firefighters: Correct AnswerJudge Roof Safety Which of the size-up indicators is not directly related to building construction Correct Answer-Adjacent exposures What is defined as the maximum heat that can be produced if all combustible material in a given area burns Correct Answer-Fuel Load What BEST describes an outcome of heavy content fuel loading Correct Answer-Fire can overwhelm the capabilities of the fire suppression system What is the critical temperature for steel trusses Correct Answer-1,000oF (538oC) In a bowstring truss roof what is fastened at the truss ends with U-shaped steel heels Correct Answer-Top and bottom chord members Additional fuel loads and ignition sources brought by building contractors are factors that: Correct Answer-Cause the risk of fire to rise sharply Preventative structural collapse potential can be identified during: Correct Answer-Preincident surveys After the emergency part of an incident is over structural collapse potential is: Correct Answer-The same as during the incident Post suppression activities and the buildup of water from suppression increase ______ in the decay state. Correct Answer-Collapse Potential What increases structural collapse potential but may not be visible during pre incident surveys Correct Answer-Storage Every U.S. gallon of water used during fire suppression adds how much pressure to floors Correct Answer8.33 pounds When a collapse is imminent, firefighters should first: Correct Answer-Inform command and all others in the buildings [Show More]
Last updated: 1 year ago
Preview 1 out of 28 pages
Instant download
Instant download
Connected school, study & course
About the document
Uploaded On
Jul 01, 2022
Number of pages
28
Written in
This document has been written for:
Uploaded
Jul 01, 2022
Downloads
0
Views
93
In Browsegrades, a student can earn by offering help to other student. Students can help other students with materials by upploading their notes and earn money.
We're available through e-mail, Twitter, Facebook, and live chat.
FAQ
Questions? Leave a message!
Copyright © Browsegrades · High quality services·